This volume presents the contributions of the 25th Southern Biomedical Engineering Conference, held in May 2009 in Miami, Florida. The papers of this Proceedings volume present new developments in theory, concept, application, and techniques in all facets of Biomedical Engineering. The broad spectrum of topics includes: Optical Imaging, Instrumentation, Biomaterials-Mechanical, Rehabilitation, Image Processing, Orthopedics, Nanomaterials, Algorithms Neural, Sensors, Tissue Engineering, Signals and Systems, Cardiovascular Systems, and Drug Delivery

1;About SBEC;10 2;Contents;11 3;Fluorescence Tomographic Imaging Using a Hand-Held Optical Imager: Extensive Phantom Studies;21 4;Clinical Translation of a Novel Hand-Held Based Optical Imager: In Vitro and InVivo Studies;23 5;Real-Time Imaging of Circulating Individual Blood Cells in Mammalian Embryos with Doppler SSOCT;25 6;Brain Connectivity Studies of Joint Attention Using Frequency-Domain Diffuse Optical Imaging;27 7;Novel Video-FRAP Method for the Determination of Anisotropic Diffusion: Principles and Optimization;29 8;Ultra High-Resolution Optical Coherence Tomography for Ocular Imaging of Small Animals;31 9;Incorporation of Interoperability in a Robot-Assisted Orthopedic Surgery System;33 10;Exploring the Effects of Cognitive Load on Muscle Activation during Functional Upper Extremity Tasks;37 11;Design and Evaluation of a Three Dimensional Ultrasound System for Tissue Ablation for Treatment of Kidney Tumors;39 12;Design and Construction of a Novel Surgical Instrument Applicable in Esophagectomy;41 13;Additive Layered Manufacturing of Reticulated Ti-6Al-4V Biomedical Mesh Structures by Electron Beam Melting;43 14;Osteointegration of HA-Coated Subperiosteal Dental Implants: Preliminary Work;49 15;Nanoscale Hole Fabrication in Cylindrical Devices for Bubble Generation;51 16;Corrosion Behavior of Electropolished and Non-electropolished Ternary Nitinol Alloys;53 17;Flowchart for Basic Non-destructive Testing Technologies in Biomaterials;55 18;The Effects of Visual and Verbal Feedback upon Gait Biomechanics and Functionality;59 19;Analysis, Assessment, and Evaluation of Postural Instability for Bipedal Locomotion;65 20;Dynamic Response of Wheelchair Cushions;67 21;Force Production and Neuromuscular Function in Bilateral Movements among Young Females at Low and High Speeds;71 22;Trunk Kinematics during Pediatric Gait;75 23;A Respiratory Gating System for PET Imaging of Lung Cancer;79 24;Quantitation of Metabolic Change in Serial FDG-PET Brain Scans of Pediatric Patients with Traumatic Brain Injury;81 25;Comparison of Respiratory Motion Correction Methods in PET Lung Tumor Quantification;83 26;Using Two-Dimensional Edge Detection to Produce Three-Dimensional Medical Prototypes from MRI Data;87 27;New Image Processing Algorithm for ROI Extraction in Patients with Rheumatoid Arthritis;91 28;A Novel Method to Study DICOM Tags and Definitions for Structured Report and Image Analysis Purposes;93 29;Visual Display for the Acquisition of High Rate Pattern Reversal Electroretinograms;95 30;System to Control Skin Temperature during Hyperthermic Treatment;97 31;Design of Interoperability-Coupled Safe Infusion Therapy in a Telemetry Setting;101 32;Endobronchial Intratumoral Chemotherapy (EITC) for Improved Treatment of Lung Cancer;105 33;Evaluation of the Electromagnetic Compatibility of WiFi Technology with Life- Supporting Medical Devices;107 34;Performance of Optimal IMC and PID Controllers for Blood Pressure Control;109 35;Biomechanical Evaluation of the Cylindrical TI Mesh Cage for the Treatment of Segmental Defects of the Tibia;115 36;A-Mode Ultrasound Bone Registration for Computer-Assisted Knee Surgery: Calibration and Robustness Test;117 37;Biomechanical Analysis of UCBL with Articulated Ankle AFO in a Surgical Stage II Posterior Tibial Tendon Dysfunction;121 38;Investigating the Tightening Torque of an Osseointegrated Transfemoral Implant System;123 39;Effects of Temperature on the Performance of Footwear Foams Subjected to Quasi- Static Compression Loading;127 40;Identification of Biomarkers for Multi-walled Carbon Nanotube Exposure in Mouse Macrophage Cells;131 41;Development of Cell Impedance Based Sensing System for the Nanotoxicity Assay;133 42;Characterization of Nanometric Qdots by AFM and Optical Microscopy;135 43;Macrophage Response to Zinc Oxide Nanorod Surfaces -Topography and Toxicity;139 44;Adhesion Dynamics of Functional Nanoparticles for Targeted Drug Delivery;141 45;The Merit of Principal Component Analysis in
ISBN 9783642016974
Artikelnummer 9783642016974
Medientyp E-Book - PDF
Auflage 2. Aufl.
Copyrightjahr 2009
Verlag Springer-Verlag
Umfang 386 Seiten
Sprache Englisch
Kopierschutz Digitales Wasserzeichen